KS1000 X-DEK Suuresildeline katusepaneel
-
Kasutusvaldkond -
Kasutamine
X-dek on rullmaterjaliga kaetav soojustatud lamekatusepaneel, mis sobib kõikide hoonete lamekatuste ehitamiseks, välja arvatud madala sisetemperatuuriga hooned.
Paneel on vajaliku konstruktsioonilise tugevuse ja jäikusega ning hea soojusisolatsiooniga. Veetõkkena paigaldatakse rullmaterjal pärast paneelide montaaži.KS1000 Xd paneelid sobivad:
- lamekatustele kaldega > 1%;
- haljastatud katuste rajamiseks;
- tavapaneelidena, aga ka osana terastarindist;
- pikkade sillete puhul.

-
Tootespetsifikatsiooni tabel -
KS1000 X-DEK / TR20

KS1000 X-DEK / TR27

KS1000 X-DEK / Steel

KS1000 X-DEK / PVC
d– südamiku paksus (mm)80100D– üldmõõdud (mm)188208Kaal (kg/m2), metall 0.9/0.7 mm21,422,2Kaal (kg/m2), TR2015,916,8Kaal (kg/m2), TR2715,816,7Toote lubatavad kõrvalekalded
Pikkus - 5 mm + 5 mm Laius - 2 mm + 2 mm Paksus - 2 mm + 2 mm Lõpulõike ristseis - 3 mm + 3 mm Tasasus (meetri kohta) - 2 mm + 2 mm Paneelide pikkus
Paneeli standardpikkus on 2,5 meetrist kuni 13,5 meetrini. Paneele pikkusega 13,5–15 m on võimalik tellida kokkuleppel Kingspani esindusega. Kõik paneelid on toodetud tagasilõikega (alumine trapetsprofiliga terasleht on pikem). Standardne tagasilõige on 50 mm, suurim võimalik tagasilõige on 630 mm.
-
Toote andmed -
Kattematerjalid:
SisekattematerjalKuumtsingitud terasplekk vastavalt standardile EN 10326:2004, mida on viimistletud 25 mikromeetri paksuse polüestriga
(standardvärvus RAL 9002). Teraspleki standardpaksused on 0,9 ja 1,1 mm.Väliskattematerjal:Kuumtsingitud terasplekk vastavalt standardile EN 10326:2004. See on 0,7 mm paksune galvaniseeritud terasplekk, millel on 5 mikromeetri paksune läbipaistev liimkile. Väliskatte pro�ilid on minibox (I) või sile (F).TR20 – bituumeniga immutatud klaaskiudmaterjal, mis sobib mitmekihiliseks kinnisulatamiseks.
TR27 – klaasriidest kate, mis sobib ühekihiliste PVC- või EPDM-kilede mehaaniliseks kinnitamiseks või kleepimiseks.Soojusisolatsioonisüdamik
Isophenic (IPN) on suletud kärgstruktuuriga HCFC-vaba isolatsioonisüdamik, mille nimitihedus on 40 kg/m3. Südamiku tellitavad paksused on 80 ja 100 mm.Tihendid
Tehases paigaldatud külgtihend
Kõikidele küljeühendustele on tehases paigaldatud kondenseerumisvastane tihendusriba (PE).
-
Toote omadused -
Thermal Insulation
λ=0,022 W/mK:Panel Thickness (mm)
R value
[(m2K)/W]
U Value
[W/m2K]
80 / Option I
4,21
0,23
80 / Option II
4,03
0,24
100 / Option I
5,12
0,19
100 / Option II
4,86
0,20
Biological
Kingspan panels are normally immune to attack from mould, fungi, mildew and vermin, no urea formaldehyde is used in the construction, and the panels are not considered deleterious.Fire
Kingspan KS1000 X-DEK roof panels has been tested according to EN1365 as load bearing roof element. The ratings achieved are presented in the table below:Panel Type
FIRE Rating
Max. bending
moment
KS1000 X-DEK 80 TR20
REI 15
6.621 kNm
KS1000 X-DEK 100 TR27
REI 15
7.725 kNm
KS1000 X-DEK 100 (steel)
REI 30
7.725 kNm
Acoustics
KS1000 X-DEK (X-dekTM) panels have acoustic parameters as below:Parameters according to Type of panel EN ISO 717-1:1999
Type of panel
RA1 [dB]
RA2 [dB]
RW [dB]
KS1000 X-DEK 80/100
26
23
27
KS1000 X-DEK 80/100
TR20/TR27
25
22
26
-
Paigaldamine -
Site Handling and Installation
Typically the panels are stored in bundles crown-to-crown manner, for turning the panels (50%) there is recommended to use special vacuum-pump device with a 180° rotation unit. The equipment is called RotaBoy. The RotaBoy equipment can be obtained directly from the Manufacturer – Viavac, or can be hired from local ViaVac office or their representative. Address of the nearest office you can find at http://www.viavac.com/.When panels are supplied with a plastic protective film this should be removed immediately after site installation. Site assembly instructions are available from the Kingspan Technical Services.

Sealants & Fillers
The panels need to be fitted as close together as possible to assure a certain airtightness. At each side joint it is necessary to apply butyl rubber sealing tape. For further panels stability, proper joint tightness and alignment, and fire-resistance of the KS1000 X-DEK panels, the stitching screws must be applied along the side lap of the panels. The stitching screws are usually applied from the bottom side of roof, however the application from the top is also possible. Recommended distance of the stitching screws are:- ≤ 500mm – for the applications where fire resistance is required
- 500÷1000mm – for the applications where fire resistance is not required.
Build speed
- Fast Build cuts site time by 100% – reduces prelims and attendance costs
- Maximises investor/occupier trading income opportunity
- Factory manufactured system facilitates zero defect installation and build quality

-
Kvaliteet ja garantii -
Quality and durability
Kingspan Insulated panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with ISO9001 standard, ensuring long term reliability and service life.Guarantees & Warranties
Kingspan will provide external coating and product warranties and guaranties on an individual project basis. -
Haljastatud katused -
Haljastatud katused
Vähest hooldust vajavad ehk ekstensiivsed haljastatud katused on alad, millel kasvav taimestik sarnaneb looduses leiduvatele taimekooslustele ja mis kasvavad ise. Nendele aladele istutatakse taimed, mis peavad vastu ka karmidele tingimustele ja on suure isetaastumisvõimega. Sellised peamiselt isekasvavad aiad koosnevad sammaldest, murust ja kukeharjalistest. Taimestik kasvab looduslikes tingimustes.Hooldust vajavatel ehk intensiivsetel haljastusega katustel võivad olla väikesed või keskmise suurusega põõsad, muru ja üksikud puud. Need võivad paikneda ühel tasapinnal, olla astmelised või moodustada saarekesi. Sealsed taimed vajavad korrapärast kastmist ja väetamist.